{"product_id":"80050","title":"Fume Monitor Badge","description":"\u003cp\u003eThe fume monitor can be worn as a badge near the breathing zone to measure personal exposure, or placed in a room to measure area concentration.\u003c\/p\u003e\u003ch3\u003eWorkplace Exposure Monitoring\u003c\/h3\u003e\u003cp\u003eMeasurement of personal exposure is very easy. Clip the monitoring badge near the breathing zone of the worker. Record the start time and the stop time of the test on the pouch of the badge and return it to the laboratory for analysis in the mailer provided. The analysis report will show the average concentration of the worker’s personal exposure level.\u003c\/p\u003e\u003cp\u003eAccording to OSHA regulations, each person who uses a toxic gas as a regular part of their job must have their exposure monitored periodically.\u003c\/p\u003e\u003ch3\u003eIndoor Air Monitoring\u003c\/h3\u003e\u003cp\u003eLeave the badge in the area at least 5 ft off the floor for 24 hours. No need to hire expensive consultants. Record the start and stop times and send the badge back to the laboratory for analysis in the mailer provided. The analysis report explains if the concentration level of your home is exceeding the exposure limit. \u003c\/p\u003e\u003ch3\u003ePrinciple of Operation\u003c\/h3\u003e\u003cp\u003eAir diffuses through a micro-porous membrane and collects vapor on specially prepared adsorbents inside the monitoring badge.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch1\u003eHow it Works\u003c\/h1\u003e\u003cp\u003e\u003cem\u003eOur monitors are available in the form of “badges” that are worn by the employee during a sampling period. There’s no liquid or metal mechanics involved in our badge sampling, so the process is not cumbersome at all.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003eAs for how the badge works, there is a microporous membrane that chemical vapors pass through. Under the membrane are special adsorbents that collect the vapors at a fixed rate. Our badges meet and exceed OSHA requirements, and OSHA\/NIOSH validated methods are used in ACS’s AIHA-LAP, LLC-accredited laboratory.\u003c\/p\u003e\u003cp\u003eOur badges:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCost less.\u003c\/li\u003e\n\u003cli\u003eDon’t need training.\u003c\/li\u003e\n\u003cli\u003eDon’t interfere with a worker’s activities.\u003c\/li\u003e\n\u003cli\u003eTest indoor air and personal exposure to toxic chemicals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eHere’s how personal exposure in the workplace is tested using our monitoring badges:\u003c\/p\u003e\u003ch2\u003eStep 1: Expose the badge\u003c\/h2\u003e\u003cp\u003eWorkers clip the badge in or near a breathing zone, most likely on their person, to measure their personal exposure level to certain chemicals. Badges can be placed in rooms to measure the concentration of chemicals in the air. When clipped on a person, the badge is small and lightweight enough to not interfere with worker activities.\u003c\/p\u003e\u003ch2\u003eStep 2: Record Start Time and Stop Time\u003c\/h2\u003e\u003cp\u003eRecord the requested information on the outside of the pouch that will enclose the badge after testing is complete. The required information includes the start time and stop time of testing.\u003c\/p\u003e\u003ch2\u003eStep 3: Return the Badge for Analysis\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFast Turnaround Time\u003c\/li\u003e\n\u003cli\u003eReliable Results\u003c\/li\u003e\n\u003cli\u003eTested in an AIHA-LLP, LLC Accredited Laboratory\u003c\/li\u003e\n\u003cli\u003eThe Lab is NY ELAP Accredited\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhen the test is finished, put the badge back into the pouch, make sure the ziplock is completely sealed, and mail it back to our lab for analysis. Our normal turnaround time is 72 hours after samples have been received.  Some chemical analysis may take longer than 72 hours.  Reports can be emailed, faxed, or mailed.\u003ca href=\"https:\/\/acsbadge.com\/wp-content\/uploads\/image2.jpg\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003eWorkers can clip the badge near the breathing zone to measure person exposure level or place it in a room to measure area concentration.  Badges are small and lightweight and do not obstruct the worker activities.\u003c\/p\u003e\u003ch3\u003eFor Testing Indoor Air Quality or Area Monitoring\u003c\/h3\u003e\u003cp\u003eSimply leave the badge in the area for 24 hours.\u003c\/p\u003e\u003cp\u003eTo test indoor air quality of your lab, leave the badge in the area at least 5 ft off the floor for 24 hours.  No need to hire expensive consultants.\u003c\/p\u003e\u003ch2\u003e\u003ca href=\"https:\/\/acsbadge.com\/wp-content\/uploads\/image4.jpeg\"\u003e\u003c\/a\u003e\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\n\u003cbr\u003eOSHA\u003c\/th\u003e\n\u003cth\u003eNIOSH\u003c\/th\u003e\n\u003cth\u003eACGIH\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTWA (ppm)\u003c\/th\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e0.016\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSTEL\/CEIL (ppm)\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e C 0.1 (15 min)\u003c\/td\u003e\n\u003ctd\u003e C 0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAKA\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CAS#\u003c\/th\u003e\n\u003ctd\u003e 50-00-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Analytical Method\u003c\/th\u003e\n\u003ctd\u003eNIOSH 2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbent\u003c\/th\u003e\n\u003ctd\u003e Silica coated with DNPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Level of Quantitation\u003c\/th\u003e\n\u003ctd\u003e0.01 PPM for 8 Hours\u003cbr\u003e0.3 PPM for 15 Minutes\u003cbr\u003e0.002 PPM for 24 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Recommended Sampling Time\u003c\/th\u003e\n\u003ctd\u003e Workplace: 15 minutes to 8 hours\u003cbr\u003eIndoor Air: 24 hours – 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Interferences\u003c\/th\u003e\n\u003ctd\u003e No interferences are known\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Effect of Temperature\u003c\/th\u003e\n\u003ctd\u003e Less than 10% for each 10°C variation from 24°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Effect of Humidity\u003c\/th\u003e\n\u003ctd\u003e No effects detected at 30% RH to 92% RH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Accuracy\u003c\/th\u003e\n\u003ctd\u003e Meets or exceeds OSHA accuracy requirements of +\/- 25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage Conditions\u003c\/th\u003e\n\u003ctd\u003e Store at room temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Recommended Holding Time\u003c\/th\u003e\n\u003ctd\u003eMonitors need to be returned to Lab within two weeks after sampling.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Rankin","offers":[{"title":"Formaldehyde","offer_id":46500389126356,"sku":"80050","price":61.86,"currency_code":"USD","in_stock":true},{"title":"Xylene","offer_id":46500389159124,"sku":"80051","price":61.86,"currency_code":"USD","in_stock":true},{"title":"Ethanol","offer_id":46500389191892,"sku":"80052","price":61.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0252\/1759\/7519\/files\/rankin-consumables-formaldehyde-fume-monitor-badge-36037813469396.jpg?v=1779422425","url":"https:\/\/shop.rankinbiomed.com\/products\/80050","provider":"Rankin Biomedical","version":"1.0","type":"link"}